Description
Selection Table
TYPE | DIMENSIONS A x B x C x D (mm) | MAX AXIAL RESTRAINT (daN) |
SC.F.1 | 25 – 8 – 40 – 70 | 30 |
SC.F.2 | 50 – 8 – 40 – 70 | 60 |
Anti-vibration wall connection SC.F is used in order to add structural integrity of long and tall gypsum board walls, which are mounted on antivibration pads or based on floating floor. It prevents any direct connection between the double walls, and increases their stiffness. Additionally it prevents wall backling during earthquakes. It is useful when a secondary wall is applied for improved sound insulation where rigid connections will cause an unwanted sound bridge.
SC.F consists of a metal sheet, suitable modulated. The antivibration polyurethane elastomer Regufoam® sheet is placed internally to absorb positive and negative axial forces. The pass-through screw does not come in contact with the metal frame, so that no sound bridge is created.
TYPE | DIMENSIONS A x B x C x D (mm) | MAX AXIAL RESTRAINT (daN) |
SC.F.1 | 25 – 8 – 40 – 70 | 30 |
SC.F.2 | 50 – 8 – 40 – 70 | 60 |